To remove childproof safety cap, push down while turning.
- Fill a clean test tube with 5 ml of water to be testedย (to the line on the tube).
- Add 6 drops from Phosphate Test Solution Bottle #1,ย holding dropper bottle upside down in a completely vertical positionย to ensure uniformity of drops added to the water sample.
- Cap the test tube and gently shake several times to mixย solution. Attention! Always use the cap. Avoid skin contactย as this may affect the test results.
- Add 6 drops from Phosphate Test Solution Bottle #2,ย holding dropper bottle upside down in a completely verticalย position to ensure uniformity of drops to the water sample.
- Cap the test tube and shake for 5 seconds.
- Wait three minutes for the color to develop.
- Read the test results by matching the color of the solutionย against those on the Phosphate Test Color Chart.
Corrective Actions:
To reduce phosphate, perform partial waterย changes and use MaxOut, or MaxOut Proย all-in-one filter media products, or FritzZymeย 360/460.
To increase phosphate, add Fritz pHย Neutralizer or any high-phosphateย supplement or fish food, or perform partialย water changes with tap water high inย phosphate.